Comparison of click and CE-chirp-evoked human auditory brainstem responses: a preliminary study
Vida Khorsand Sabet1, Mohammad-Ebrahim Mahdavi-Zafarghandi1, Mozhdeh Safavi1, Marzieh Sharifian1, Seyyed Mahdi Tabatabaee2
1- Department of Audiology, Faculty of Rehabilitation Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
2- Department of Biostatistics, Faculty of Rehabilitation Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Abstract:   (19859 Views)

Background and Aim: CE-Chirp stimulus has been developed for stimulating more apical regions of the cochlea. Inadequacy of clinical information on the latency and amplitude characteristics of ABR evoked by CE-chirp at different levels in addition to discrepancy in identifying earlier ABR waveforms using CE-chirp stimulus are the reasons of this study.

Methods: This study was done by recoding ABR to click and broad-band CE-chirp stimuli in the right ear of 15 non-randomly selected normal-hearing individuals with age range of 20-30 years old. Frequency of recordable waves I and III, as well as threshold, amplitude, and latency of wave V were compared in response to click and CE-Chirp at 20-80 dB nHL.

Results: At 80 dB nHL, click stimulus evokes waves I and III more frequently than chirp stimulus (p=0.012 and p=0.016 respectively). At 20 and 40 dB nHL, wave V latency evoked by CE-Chirp is significantly longer than wave V latency evoked by click (p=0.012 and p=0.0001 respectively) however, at 80 dB nHL wave V latency evoked by CE-Chirp is shorter than click (p=0.0001). Wave V amplitude for CE-Chirp is significantly larger than for click at levels of 20, 40 and 60 dB nHL (p=0.0001, p=0.0001 and p=0.013 respectively). Wave V threshold is approximately 5 dB lower with CE-chirp compared to click (p=0.014).

Conclusion: Except at high levels, CE-Chirp evokes wave V with larger amplitude and lower threshold than click. Possibility of recording earlier ABR waves is reduced with CE-chirp stimulus.

Keywords: Auditory brainstem responses, chirp, click, normal hearing
Full-Text [PDF 181 kb]   |   Full Text (HTML)   (2780 Downloads)    
Type of Study: Research |
Received: 2013/08/15 | Accepted: 2014/02/17 | Published: 2014/02/26
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print



Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 23, Issue 4 (10-2014) Back to browse issues page
شنوایی شناسی - دانشگاه علوم پزشکی تهران Bimonthly Audiology - Tehran University of Medical Sciences
Creative Commons Attribution-NonCommercial 3.0

This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.

Persian site map - English site map - Created in 0.15 seconds with 31 queries by YEKTAWEB 4610