|||  Journal title: Audiology | Publisher: Tehran University of Medical Sciences | Website: http://aud.tums.ac.ir | Email: aud@tums.ac.ir   |||
   [Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Registration :: Submission :: Current Issue :: Archive :: Contact :: Search ::
:: Volume 23, Issue 3 (8-2014) ::
aud 2014, 23(3): 75-81 Back to browse issues page
Comparing human electrocochleography responses to click and chirp stimuli
Minoo Karimi1, Mohammad-Ebrahim Mahdavi-Zafarghandi1, Homa Zarrinkoob1, Mozhdeh Safavi1, Seyyed Mehdi Tabatabaee2
1- Department of Audiology, Faculty of Rehabilitation Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
2- Department of Biostatistics, Faculty of Rehabilitation Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Abstract:   (13010 Views)

Background and Aim: It is not known how electrocochleography components of action potentials (AP) and summating potentials (SP) are changed in response to CE-chirp stimulus using extra-tympanic electrodes. This study was done for comparing summating potentials and action potentials specifications in response to CE-chirp and click stimuli.

Methods: Electrocochleography components of action potentials and summating potentials were recorded in 16 normal hearing subjects (8 men and 8 women) aged 22-30 years (mean: 26.7 with SD 2.5 years) with audiometric (250-8000 Hz) hearing thresholds of 15 dB HL or better in response to click and CE-chirp stimulus at 90 dB nHL. Amplitude, duration, latency and area of summating potentials and action potentials and SP/AP amplitude and area ratios were compared.

Results: Among the measured parameters, action potentials amplitude in response to CE-chirp stimulus (0.41 with SD 0.26 µV ) was significantly smaller than action potentials amplitude in response to click (0.61 with SD 0.29 µV ) stimulus (p<0.005). Relative frequency of detecting summating potentials in response to CE-chirp (68.7%) was lower than (100%) click (p<0.005).

Conclusion: Recording electrocochleography component of summating potentials and action potentials with CE-chirp stimulus at high intensity level in normal hearing individuals shows no advantage over click stimulus. Small amplitude of summating potentials as a major problem of extra-tympanic electrocochleography cannot be solved using CE-chirp stimulus.

Keywords: Electrocochleography, summating potential, action potential, chirp, click
Full-Text [PDF 160 kb]   |   Full Text (HTML)   (3108 Downloads)    
Type of Study: Research |
Received: 2013/08/16 | Accepted: 2013/10/22 | Published: 2014/02/19
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print



Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 23, Issue 3 (8-2014) Back to browse issues page
شنوایی شناسی - دانشگاه علوم پزشکی تهران Bimonthly Audiology - Tehran University of Medical Sciences
Creative Commons Attribution-NonCommercial 3.0

This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.

Persian site map - English site map - Created in 0.14 seconds with 31 queries by YEKTAWEB 4610